Property Description: |
(2) story house with daylight basement and garage |
Property size: |
2,253 s.f. per listing |
Occupancy Status: |
Vacant (under construction) |
Inspection Date: |
11/28/2011 |
Inspection Time: |
9:10 A.M. – 1:00 P.M. +- |
Weather Conditions: |
Clear, 45 deg F +- |
Table of Contents
Summary of Inspection....................................................................................................... 3
Electrical System................................................................................................................. 5
Plumbing System................................................................................................................. 7
Water Heater....................................................................................................................... 8
Heating System................................................................................................................... 9
Site..................................................................................................................................... 11
Building Exterior............................................................................................................... 14
Garage............................................................................................................................... 16
Living Room...................................................................................................................... 18
Powder Room.................................................................................................................... 19
Kitchen and Nook............................................................................................................. 20
Hallways............................................................................................................................ 22
Master Bedroom Suite....................................................................................................... 24
Bedrooms 2 and 3............................................................................................................. 25
Main Bathroom.................................................................................................................. 26
Utility Room...................................................................................................................... 27
Family Room..................................................................................................................... 29
Attic................................................................................................................................... 30
Structural Pest Inspection Diagram................................................................................... 31
All items listed in the Summary of each section are listed below. Additional comments may be written in the body of the report. Please read the entire report. All items listed below should be further evaluated, inspected, modified, and/or corrected by a licensed professional in that corresponding or related trade.
WDO refers to “Wood Destroying Organism” as defined by the Washington State Department of Agriculture
- Items in this font are general comments throughout report.
- Items in this font are considered a minor cost and/or cosmetic.
- Items in this font are considered a substantial cost or an extreme safety concern.
General
- New construction. Provide certificate of occupancy
- Final clean house and windows once complete
- Verify all survey pins are in place identifying property corners
- Install all window screens
Electrical System
- Electrical ground wire is cut at the exterior. Ground rods not visible
Plumbing System
Water Heater
Heating System
- Thermostat at floor 1 is not level
- Filter compartment is located in furnace which is located in the attic. Recommend move filter location to return air grills. Grills would need to be replaced with the type that open with hinges on (1) side for filter installation and replacement.
Site
- Grade of structure is not in compliance with current building code or generally accepted building practices. Primary improperly graded areas are the rear yard, and North side. Maintain minimum 6” clearance between ground and siding
- Rear porch has substantial settlement
- Remove concrete debris from rear yard
- Question: Is there a recorded easement in place for the overhead power lines that cross the property ? Who is responsible and liable for maintaining the tree growth that will affect these power lines ?
- Platform for propane tank has settled. Platform and tank are not level
- Provide written acknowledgement by the local public works department and or building department that the owner of this property is not responsible for the condition of the curbs or asphalt in front of this property
Building Exterior
- Paint at trim boards has flacked off at several locations. Siding (paint) is covered with mud at numerous locations
- Horizontal trim board should have been flashed. All gaps at the top side of these boards must be caulked and maintained to prevent moisture damage
- Roof at bay window has ridge shingles that do not lay flat
Garage
- Holes in drywall are to be sealed (this condition is a breach in fire separation between house and garage)
- Garage door opener prewire should be installed at an appropriate height
Living Room
- Window sill at window to right of fireplace is not (close to) level
Powder Room
- Clean paint from bathroom side of door
- Towel bar is dented
Kitchen and Nook
- Drywall repairs visible at stairwell (workmanship). It may be necessary to repaint the entire ceiling
- Interior skin of cabinet is extensively damaged at left upper cabinet. Other upper cabinets are not fully secured (loose screws)
- Cabinet doors are not properly aligned
- Sink base cabinet face plate is not installed
- Remove construction materials at top of (above) cabinets
- Countertop laminate is not secure to sub-top; primarily at pass thru to nook
- Countertop edge near sliding glass door needs touch up
- Install oversize electrical plate cover at outlet for ventilation hood to cover adjacent cabinet damage
- Fixed panel of Kitchen window appears to be scratched
- Clean paint from sliding glass door frame (upper areas of fixed panel)
Hallways
- Drywall repairs visible at stairwell (workmanship). It may be necessary to repaint the entire wall
- Poor workmanship at carpeting on top of back-framing wall. Recommend remove carpeting and replace with trim (same as a wall cap)
- Single hung window at floor 1 landing is not properly functioning
- Stain ends of half wall caps at floors 1 and 2
- Baseboard is loose from wall at floor 1 at hallway to Living Room
Master Bedroom Suite
- Casing joint is not tight at bathroom side of door (upper right corner)
Bedrooms 2 and 3
- Touch up drywall at closet in rear bedroom
- By-pass door guides not installed
Main Bathroom
- Touch up drywall be electrical outlet and hole in wall by towel bar
- Complete caulking (near toilet area) at vinyl floor to tub
Utility Room
- Metal debris in washing machine outlet (potential shock hazard)
Family Room
- Provide explanation of defect and repair regarding prior moisture intrusion at garage and basement. Photos should be included if available
- Door latch needs adjustment (latching mechanism sticks)
- Substantial air leakage at upper left side of door to garage. Leak is likely between the door jamb and wall areas
Attic
|
|
|
No evidence of over-heating |
|
|
|
Service
|
|
Type: |
Underground |
Meter Location: |
Side of garage |
Voltage: |
240 |
|
|
|
|
Panel
|
|
Location: |
Garage |
Manufacturer: |
Siemens |
Type: |
Dual bus bar |
Panel Rating: |
200 AMP |
Main Disconnect: |
200 AMP |
Serv. wire Size/ Rating: |
200 AMP |
Sub-panel: |
No |
Grounding: |
- Electrical ground wire is cut at the exterior. Ground rods not visible |
Panel Clearance: |
30” wide, 3’ in front as required |
|
Electrical ground wire is cut |
|
|
|
|
|
Breakers/ Wiring
|
|
Type: |
Copper romex |
Breakers: |
No visible defects |
|
- Arc fault breakers tested |
|
|
Domestic Water
|
|
Supply: |
Public water |
Supply Pipe: |
Not visible |
House Piping: |
Not visible |
Pipe Condition: |
Not visible |
Main Water Shut off: |
@ garage |
|
Domestic Water Shut off |
|
Wintertime shut off for hose bib |
|
|
|
|
|
Sanitary Sewer
|
|
Discharge: |
Public sewer |
House Piping: |
ABS where visible |
Pipe Condition: |
Satisfactory where visible |
|
|
|
Water Heater
|
|
Location: |
Garage |
Make/ Model: |
Bradford White s/n HG15269545 |
Fuel Type: |
Electric |
Capacity: |
50 gallon |
|
|
|
|
Useful Life
|
|
Est. Useful Life new: |
12 years |
Est. age of heater: |
1 year +- |
|
|
|
|
Safety
|
|
TMP valve: |
As per required |
Earthquake Straps: |
Installed |
Expansion Tank: |
Installed |
Safe water temperature: |
120 deg F per industry standards |
|
No hot water in expansion tank Tank is functioning properly |
|
|
|
|
|||||
|
Furnace
|
|
|||||
|
Location: |
Attic |
|
||||
|
Make/ Model: |
Nordyne s/n E3E110403746 |
|
||||
|
Fuel Type: |
Electric |
|
||||
|
BTUH Output: |
53,000 |
|
||||
|
|
|
|
||||
|
|
|
|
||||
|
Useful Life
|
|
|
||||
|
Est. Useful Life new: |
25 years |
|
||||
|
Est. age of furnace: |
1 year +- |
|
||||
|
|
|
|
||||
|
|
|
|
||||
|
Operation |
|
|
||||
|
Thermostat: |
Programmable @ floor 1 hall |
|
||||
|
|
|
|||||
|
|
- Filter compartment is located in furnace which is located in the attic. Recommend move filter location to return air grills. Grills would need to be replaced with the type that open with hinges on (1) side for filter installation and replacement. |
|
||||
|
|
|
|
||||
|
Furnace filter inside furnace
|
|
Industry standard is to have the filter located at the return air grills when the furnace is located in the attic |
|
|||
|
|
|
|
Heat Gain
|
|
Rating: |
- Not specified |
@ return air: |
- 79 deg F |
@ nearest register: |
- 117 deg F |
Heat Gain: |
38 deg F. Heat gain is within reasonable expectations for this type of furnace |
|
Temperature measured at return air |
|
Temperature measured at heat register |
|
|
|
Site
|
|
Grade at structure: |
|
|
Lot shall be graded so that the grade away from the foundation falls a minimum of 6" within the first 10 feet. Distance from top foundation to grade shall not be less than 6 inches. IRC.R-401.3. EXCEPTION: Where lot lines, walls, slopes or other physical barriers prohibit 6 inches (152mm) of fall within 10 feet (3048mm), the final grade shall slope away from the foundation at a minimum slope of 5 percent and the water shall be directed to drains or swales to ensure drainage away from the structure. Swales shall be sloped a minimum of 2 percent when located within 10 feet (3048mm) of the building foundation. Impervious surfaces within 10 feet (3048mm) of the building foundation shall be sloped a minimum of 2 percent away from the building. |
Earth to wood contact: |
Clearance as required |
Vegetation contact: |
Negligible |
Roof drain discharge: |
Underground discharge |
|
Standing water at rear yard
|
|
Reverse grade at rear yard Grade at house could be raised to 6” of the siding |
|
|
|
|
|
Driveway
|
|
Type: |
Concrete |
Condition: |
Satisfactory |
Trip Hazard: |
None |
|
|
|
|
Front walks/ steps
|
|
Type: |
Concrete |
Condition: |
Satisfactory |
Trip Hazard: |
None |
|
|
|
|
Rear walks/ steps
|
|
Type: |
Concrete |
Condition: |
|
|
|
Trip Hazard: |
None |
|
Settlement at rear patio
|
|
Settlement at rear patio Moisture barrier should be installed between the siding and concrete. Vertical groves in the siding must be sealed to prevent moisture intrusion and wood rot |
|
|
Concrete debris at rear yard |
|
|
|
|
|
Miscellaneous
|
|
Overhead Power Lines: |
Yes |
|
|
Retaining Walls: |
None that affect structure |
Underground Oil Tank: |
No visible evidence |
Irrigation System: |
None visible |
|
- Platform for propane tank has settled. Platform and tank are not level |
|
|
Settlement at propane tank |
|
Propane tank is not level |
|
|
Overhead power lines in trees |
|
Damaged curbs |
|
|
|
General Condition
|
|
Structural Movement: |
No visible evidence |
Exterior doors: |
Satisfactory |
Windows (ext. cladding): |
Satisfactory |
|
|
|
|
Siding
|
|
Type: |
Hardboard |
Condition: |
Satisfactory |
|
|
Window/Door Flashing: |
Satisfactory |
Caulking: |
|
|
Moisture will enter gaps at siding - trim |
|
Moisture will enter gaps at siding - trim |
|
|
Painting of trim boards is peeling |
|
|
|
|
|
Roof
|
|
Estimated Pitch: |
4:12 |
Material: |
Composition |
Layers: |
1+ |
How Inspected: |
From floor 2 and from street and rear yard |
Condition: |
Satisfactory |
|
- Roof at bay window has ridge shingles that do not lay flat |
Ventilation: |
Eave and roof vent |
Plumbing Vents: |
Satisfactory |
Flues: |
Satisfactory |
Flashing: |
Satisfactory |
|
Ridge shingle does not lay flat |
|
Ridge shingle does not lay flat |
|
|
|
|
|
Gutters/ Downspouts
|
|
Type: |
Continuous metal |
Condition: |
Satisfactory |
|
|
|
|
Electrical
|
|
Outlets: |
Tested, GFCI protected |
Switches/Lights: |
Tested |
|
|
|
|
Plumbing
|
|
Hose Bibs: |
Anti-siphon |
Gas Piping: |
Inspected |
Type: Attached |
|
|
General Room Condition
|
|
Visibility: |
Space is vacant |
Structural Movement: |
No visible evidence |
Moisture Infiltration: |
No visible evidence |
Walls: |
Satisfactory |
Ceiling: |
Satisfactory |
Slab: |
Satisfactory |
|
|
|
|
Safety
|
|
Fire separation: |
- Holes in drywall are to be sealed (this condition is a breach in fire separation between house and garage) |
Ignition point > above FF: |
In compliance |
Safety barricade to mech.: |
In compliance |
|
Holes in drywall are a breach in the fire separation |
|
|
|
|
|
Garage Door
|
|
Type: |
Metal roll-up |
Springs & Fasteners: |
No visible defects |
Auto Reverse: |
n/a |
Photocell reverse: |
n/a |
Remote openers: |
n/a |
|
- Garage door opener pre-wire should be installed at an appropriate height |
|
Garage door opener pre-wire is 2’ +- above the slab |
|
|
|
|
|
Electrical
|
|
Switches/Lights: |
Tested |
Outlets: |
All visible tested, GFCI protected |
|
|
|
|
Doors
|
|
Operation/latching: |
Tested |
Door condition: |
Satisfactory |
|
|
General Room Condition
|
|
Visibility: |
Room is vacant |
Structural Movement: |
No visible evidence |
Moisture Infiltration: |
No visible evidence |
Walls: |
Satisfactory |
Ceiling: |
Satisfactory |
Flooring: |
Satisfactory |
|
|
|
|
Electrical
|
|
Switches/Lights: |
All visible tested |
Outlets: |
All visible tested |
|
|
|
|
Heating
|
|
Source: |
Ceiling register |
Air Flow/ Heat Gain: |
Satisfactory |
|
|
|
|
Windows
|
|
Glazing: |
No visible defects |
Tempered: |
Not required |
Operation: |
Tested |
Screen: |
None |
|
|
|
|
Doors/Millwork
|
|
Operation/latching: |
Tested |
Door condition: |
Satisfactory |
Millwork condition: |
Satisfactory |
|
- Window sill at window to right of fireplace is not (close to) level |
|
|
|
|
Fireplace
|
|
Type: |
Sealed gas direct vent |
Tested: |
Ignition tested |
Location: Floor 1 |
|
|
General Room Condition
|
|
Visibility: |
Room is vacant |
Structural Movement: |
No visible evidence |
Moisture Infiltration: |
No visible evidence |
Walls: |
Satisfactory |
Ceiling: |
Satisfactory |
Flooring: |
Satisfactory |
Cabinets: |
Satisfactory |
Countertops: |
Satisfactory |
Mirrors: |
Satisfactory |
|
|
|
|
Electrical
|
|
Switches/Lights: |
All visible tested |
Outlets: |
All visible tested, GFCI protected |
|
|
|
|
Heating
|
|
Source: |
Adjacent spaces |
Air Flow/ Heat Gain: |
Satisfactory |
Mechanical ventilation: |
Tested |
|
|
|
|
Doors/Millwork
|
|
Operation/latching: |
Tested |
Door condition: |
Satisfactory |
|
|
Millwork condition: |
Satisfactory |
Bath Hardware: |
|
|
|
|
|
Plumbing
|
|
Functional flow: |
Appears adequate |
Hot/ Cold: |
Tested |
Drainage: |
Appears adequate |
Visible leaks: |
None visible |
Caulking: |
Satisfactory |
Toilet Secure: |
Satisfactory |
Fixtures: |
No visible defects |
Location: Floor 1 |
|
|
General Room Condition
|
|
Visibility: |
Rooms are vacant |
Structural Movement: |
No visible evidence |
Moisture Infiltration: |
No visible evidence |
Walls: |
Satisfactory |
Ceiling: |
|
Flooring: |
Satisfactory |
Cabinets: |
- Interior skin of cabinet is extensively damaged at left upper cabinet. Other upper cabinets are not fully secured (loose screws) |
|
|
|
|
|
|
Countertops: |
- Countertop laminate is not secure to sub-top; primarily at pass thru to nook |
|
|
|
|
|
Damage to interior of upper cabinet
|
|
Upper cabinet screws not set |
|
|
Cabinet doors are not aligned |
|
Loose countertop (laminate) |
|
|
|
|
|
Appliances
|
|
Dishwasher: |
Tested full cycle |
Dishwasher air gap: |
Visible |
Oven: |
Tested |
Cooktop: |
Tested |
Microwave: |
Not tested |
Ventilation: |
Tested |
Refrigerator: |
n/a |
|
|
|
|
Plumbing
|
|
Functional flow: |
Appears adequate |
Hot/ Cold: |
Tested |
Drainage: |
Appears adequate |
Visible leaks: |
None visible |
Disposal: |
Tested |
Caulking: |
Satisfactory |
Fixtures: |
No visible defects |
|
|
|
|
Electrical
|
|
Switches/Lights: |
All visible tested |
Outlets: |
All visible tested, GFCI protected |
|
- Install oversize electrical plate cover at outlet for ventilation hood to cover adjacent cabinet damage |
|
|
|
|
Heating
|
|
Source: |
Ceiling register |
Air Flow/ Heat Gain: |
Satisfactory |
|
|
|
|
Windows
|
|
Glazing: |
|
Tempered: |
As required |
Operation: |
Tested |
Screen: |
None |
|
|
|
|
Doors/Millwork
|
|
Operation/latching: |
Tested |
|
- Clean paint from sliding glass door frame (upper areas of fixed panel) |
Door condition: |
Satisfactory |
Millwork condition: |
Satisfactory |
Location: Floors 1, 2, and basement |
|
|
General Room Condition |
|
Visibility: |
Space is vacant |
Structural Movement: |
No visible evidence |
Moisture Infiltration: |
No visible evidence |
Walls: |
- Drywall repairs visible at stairwell (workmanship). It may be necessary to repaint the entire wall |
Ceiling: |
Satisfactory |
Flooring: |
Satisfactory |
|
- Poor workmanship at carpeting on top of back-framing wall. Recommend remove carpeting and replace with trim (same as a wall cap) |
|
|
|
Drywall repairs very noticeable at stairwell (both sides)
|
|
Poor workmanship at top of back-framing wall |
|
|
See image to right |
|
Cold spot at ceiling This cold area is likely the p trap for the shower in contact with the drywall. Water in the shower was run for 60 minutes +-. |
|
|
|
|
|
Electrical
|
|
Switches/Lights: |
All visible tested |
Outlets: |
All visible tested |
Smoke Detector: |
Tested |
|
|
|
|
Heating
|
|
Source: |
Ceiling register |
Air Flow/ Heat Gain: |
Satisfactory |
|
|
|
|
Windows
|
|
Glazing: |
No visible defects |
Tempered: |
Not required |
Operation: |
- Single hung window at floor 1 landing is not properly functioning |
Screen: |
None |
|
|
|
|
Doors/Millwork
|
|
Operation/latching: |
Tested |
Door condition: |
Satisfactory |
Millwork condition: |
Satisfactory |
|
|
|
- Baseboard is loose from wall at floor 1 at hallway to Living Room |
|
|
|
|
Stairwell |
|
Handrails: |
As required |
Barricades: |
As required |
Balusters: |
As required |
Trip Hazard: |
None |
Location: Floor 2 |
|
|
General Room Condition
|
|
Visibility: |
Room is vacant |
Structural Movement: |
No visible evidence |
Moisture Infiltration: |
No visible evidence |
Walls: |
Satisfactory |
Ceiling: |
Satisfactory |
Flooring: |
Satisfactory |
Cabinets: |
Satisfactory |
Countertops: |
Satisfactory |
Mirrors: |
Satisfactory |
|
|
|
|
Electrical
|
|
Switches/Lights: |
All visible tested |
Outlets: |
All visible tested. Bathroom outlets are GFCI protected |
Smoke detector: |
Tested |
|
|
|
|
Heating
|
|
Source: |
Ceiling register |
Air Flow/ Heat Gain: |
Satisfactory |
Mechanical ventilation: |
Tested |
|
|
|
|
Windows
|
|
Glazing: |
No visible defects |
Tempered: |
As required |
Operation: |
Tested |
Egress: |
Appears to meet current egress standards |
Screen: |
None |
|
|
|
|
Doors/Millwork
|
|
Operation/latching: |
Tested |
Door condition: |
Satisfactory |
Millwork condition: |
Satisfactory |
|
- Casing joint is not tight at bathroom side of door (upper right corner) |
Bath Hardware: |
Satisfactory |
|
|
|
|
Plumbing
|
|
Functional flow: |
Appears adequate |
Hot/ Cold: |
Tested |
Drainage: |
Appears adequate |
Visible leaks: |
None visible |
Caulking: |
Satisfactory |
Toilet Secure: |
Satisfactory |
Tub/Shower surround: |
Satisfactory |
Fixtures: |
No visible defects |
Location: Floor 2 |
|
|
General Room Condition
|
|
Visibility: |
Rooms are vacant |
Structural Movement: |
No visible evidence |
Moisture Infiltration: |
No visible evidence |
Walls: |
Satisfactory |
|
|
Ceiling: |
Satisfactory |
Flooring: |
Satisfactory |
|
|
|
|
Electrical
|
|
Switches/Lights: |
All visible tested |
Outlets: |
All visible tested |
Smoke Detector: |
Tested |
|
|
|
|
Heating
|
|
Source: |
Ceiling register |
Air Flow/ Heat Gain: |
Satisfactory |
|
|
|
|
Windows
|
|
Glazing: |
No visible defects |
Tempered: |
Not required |
Operation: |
Tested |
Egress: |
Appears to meet current egress standards |
Screen: |
None |
|
|
|
|
Doors/Millwork
|
|
Operation/latching: |
Tested |
|
|
Door condition: |
Satisfactory |
Millwork condition: |
Satisfactory |
Location: Floor 2 |
|
|
General Room Condition
|
|
Visibility: |
Room is vacant |
Structural Movement: |
No visible evidence |
Moisture Infiltration: |
No visible evidence |
Walls: |
- Touch up drywall be electrical outlet and hole in wall by towel bar |
Ceiling: |
Satisfactory |
Flooring: |
Satisfactory |
Cabinets: |
Satisfactory |
Countertops: |
Satisfactory |
Mirrors: |
Satisfactory |
|
|
|
|
Electrical
|
|
Switches/Lights: |
All visible tested |
Outlets: |
All visible tested, GFCI protected |
|
|
|
|
Heating
|
|
Source: |
Ceiling register |
Air Flow/ Heat Gain: |
Satisfactory |
Mechanical ventilation: |
Tested |
|
|
|
|
Doors/Millwork
|
|
Operation/latching: |
Tested |
Door condition: |
Satisfactory |
Millwork condition: |
Satisfactory |
Bath Hardware: |
Satisfactory |
|
|
|
|
Plumbing
|
|
Functional flow: |
Appears adequate |
Hot/ Cold: |
Tested |
Drainage: |
Appears adequate |
Visible leaks: |
None visible |
Caulking: |
- Complete caulking (near toilet area) at vinyl floor to tub |
Toilet Secure: |
Satisfactory |
Tub/Shower surround: |
Satisfactory |
Fixtures: |
No visible defects |
Location: Floor 2 |
|
|
General Room Condition
|
|
Visibility: |
Room is vacant |
Structural Movement: |
No visible evidence |
Moisture Infiltration: |
No visible evidence |
Walls: |
Satisfactory |
Ceiling: |
Satisfactory |
Flooring: |
Satisfactory |
|
|
|
|
Electrical
|
|
Switches/Lights: |
All visible tested |
Outlets: |
All visible tested, GFCI protected |
|
- Metal debris in washing machine outlet (potential shock hazard) |
|
|
|
Metal in electrical outlet |
|
|
|
|
|
Heating
|
|
Source: |
Ceiling register |
Air Flow/ Heat Gain: |
Satisfactory |
Mechanical ventilation: |
Tested |
|
|
|
|
Windows
|
|
Glazing: |
No visible defects |
Tempered: |
Not required |
Operation: |
Tested |
Screen: |
None |
|
|
|
|
Doors/Millwork
|
|
Operation/latching: |
Tested |
Door condition: |
Satisfactory |
Millwork condition: |
Satisfactory |
|
|
|
|
Plumbing
|
|
Functional flow: |
Appears adequate |
Hot/ Cold: |
Tested |
Drainage: |
Appears adequate |
Visible leaks: |
None visible |
Caulking: |
Satisfactory |
Fixtures: |
No visible defects |
|
|
|
|
Appliances
|
|
Washer: |
n/a |
Dryer Connection: |
Electric |
Dryer: |
n/a Vented to outside |
Appliance Condition: |
n/a |
|
|
General Room Condition
|
|
Visibility: |
Room is vacant |
Structural Movement: |
No visible evidence |
Moisture Infiltration: |
No visible evidence |
|
- Provide explanation of defect and repair regarding prior moisture intrusion at garage and basement. Photos should be included if available |
Walls: |
Satisfactory |
Ceiling: |
Satisfactory |
Flooring: |
Satisfactory |
|
- 6-mil moisture barrier required under occupied slabs. IRC R-506.(unable to verify this installation by a non-invasive home inspection) |
|
|
|
|
Electrical
|
|
Switches/Lights: |
All visible tested |
Outlets: |
All visible tested |
Smoke Detector: |
Tested |
|
|
|
|
Heating
|
|
Source: |
Ceiling register |
Air Flow/ Heat Gain: |
- Heat flow is marginal if other heat supplies in the house are fully open |
|
|
|
|
Windows
|
|
Glazing: |
No visible defects |
Tempered: |
Not required |
Operation: |
Tested |
Screen: |
None |
|
|
|
|
Doors/Millwork
|
|
Operation/latching: |
Tested |
|
|
Door condition: |
Satisfactory |
Millwork condition: |
Satisfactory |
|
- Substantial air leakage at upper left side of door to garage. Leak is likely between the door jamb and wall areas |
|
Leakage at door to garage |
|
Location: Over main body of house |
|
|
General
|
|
Visibility: |
Space is vacant |
Access location: |
Master Bedroom closet |
How viewed: |
From furnace platform |
|
|
|
|
|
|
|
|
|
Moisture
|
|
Roof Ventilation: |
Appears adequate |
Moisture Intrusion: |
No visible evidence |
Bath/Kitchen fans : |
All vent to outside |
|
|
|
|
Structural
|
|
Structure Type: |
Manufactured trusses (2 layers where visible) |
Sheathing: |
OSB |
Structural Movement: |
No visible evidence |
|
|
|
|
Insulation
|
|
Type: |
Blown in |
Condition: |
Satisfactory |
|
|
|
|
Flues/Vent Stacks
|
|
Plumbing Stacks: |
All vented to exterior |
|
|
|
|
Electrical
|
|
Outlets: |
Satisfactory |
Wiring/ junction boxes: |
No visible defects |
|
|
|
|
Structural Pests
|
|
Conducive Material: |
No visible evidence |
Visible Evidence: |
No visible evidence |
|
|
|
|
Nuisance Pests
|
|
Visible Evidence: |
No visible evidence |
Wood Destroying Organisms (WDO) |
|
Conducive Conditions (CC) |
||
WDO-AB |
Anobid Beetles |
|
CC-BG |
Bare Ground |
WDO-CA |
Carpenter Ants |
|
CC-CD |
Conducive Debris |
WDO-DT |
Dampwood Termites |
|
CC-EM |
Excessive Moisture |
WDO-MA |
Moisture Ants |
|
CC-EW |
Earth-Wood Contact |
WDO-OB |
Other Beetles |
|
CC-FC |
Failed Caulking |
WDO-RF |
Rot Fungus |
|
CC-IV |
Inadequate Ventilation |
WDO-ST |
Subterranean Termites |
|
CC-RG |
Restricted Gutter |
|
|
|
CC-VC |
Vegetation Contact |
Inspection Conditions (IC) |
|
|
|
|
IC-CSA |
Crawl Space Access |
|
|
|
IC-IA |
Inadequate Clearance |
|
|
|
|